    Humdifiers : Generalaire : 1099

Model 1099-Series

Drain-Type By-Pass Flow-Through Humidifier

Application: 

• GENERALAire’s highest capacity model delivers 23 GPD* and is ideal for today’s larger homes. *see chart at bottom of page.

• A portion of the heated air from the furnace passes through a water-soaked pad where it absorbs additional moisture and then returns for distribution throughout your home.

• Water is metered into a patented trough and dispersed uniformly across the pad. Unevaporated water drains from the bottom of the unit to eliminate mineral build-up.

• Replacement pad part number 1099-20.

• M3 Select-Control Manual Humidistat is included.

Unit Size: 16" wide x 16" high x 11" deep

Plenum Opening: 13-1/4" wide x 9-1/4" high

Bypass Duct: 7" diameter

Capacity GDP @ 120F Plenum Temp: 23

Model No.

GPD*

Loose

Average

Tight

1099 LH

23.0

2500

3538

5476

*NOTE: Figures are based on an 8ft. ceiling height. GPD shown is a 140˚ plenum temperature. Square footage may be adjusted for other plenum temperatures.

 

 

Humidity requirements in GPD based on
house size and type of construction
(from ARI Guideline F)

Type Of
Construction
SIZE OF HOUSE (sq. ft.)*
500 1000 1500 2000 2500 3000
Tight 2.1 4.2 6.4 8.5 10.6 12.7
Average 3.3 6.5 9.8 13.1 16.3 19.6
Loose 4.6 9.2 13.8 18.4 23.0 27.6
*Based on 8 ft. ceiling height

Humidity based on a 70˚F-30% relative humidity indoor conditions